Control Process DN 10

Control Process DN 10

Control system consisting of a proportional valve with a nominal diameter of DN 10 and a cable plug with corresponding electronics. The controlled system can be used optimally with the upstream measuring turbine; MT 40. The controlled…

About this product

Control system consisting of a proportional valve with a nominal diameter of DN 10 and a cable plug with corresponding electronics. The controlled system can be used optimally with the upstream measuring turbine

MT 40. The controlled system is used for the continuous control of volume flows and is suitable for drinking water and physically and chemically similar media.

The valve is normally closed (NC).

The data determined in the measuring turbine, is forwarded to the control electronics. The coil current is modulated via pulse width modulation (PWM) of the electronics. The modulation of the current and thus of the magnetic field causes a continuous raising or lowering of the valve core. This electronic system therefore provides an adjustable volume flow.

The electrical operational safety is guaranteed by the electrical insulation coordination, which corresponds to the VDE 110 regulations. The manufacturing process includes a 100% electrical safety test in accordance with the VDE 0631 Part 1000 regulations.

Due to the use of high-quality insulating materials, continuous operation (100% ED) is possible even at high ambient and media temperatures. The solenoid valve with glass-fibre reinforced polyamide housing is suitable for hot water.

The valve can only be operated with the appliance inletsupplied by A.u.K. MĂĽller.

Applications: - Thermostatically controlled heating system - Industrial appliances - Cooling and water circuits

Characteristics: - Continuous volume flow within the control range - Electronics expandable e.g. flow control to a temperature setpoint - Normally closed (NC) - Suitable for hot water up to 90°C - Optimized water hammer characteristic by low noise emission according to EN 60730 - High operating safety through the use of high quality materials and 100% final testing of the products

Technical data

Materials

Data sheet (PDF): https://www.akmueller.de/fileadmin/akmueller/products_import/datasheets/61_010_126_en.pdf